feat(openclaw): add shopping, supermarket deals, geizhals, and ebay MCP tools
This commit is contained in:
@@ -17,19 +17,73 @@ variable "sensor_innen_mac" {
|
||||
variable "taupunktschwelle" {
|
||||
type = number
|
||||
description = "Dew point difference threshold [°C] to trigger the fan (indoor_dp > outdoor_dp + threshold)"
|
||||
default = 2
|
||||
default = 2.0
|
||||
}
|
||||
|
||||
variable "mindesttemperatur" {
|
||||
type = number
|
||||
description = "Minimum indoor temperature [°C] required to run the fan"
|
||||
default = 10
|
||||
description = "Minimum indoor temperature [°C] required to run the fan (frost / cold protection)"
|
||||
default = 10.0
|
||||
}
|
||||
|
||||
variable "mindesthumi" {
|
||||
variable "max_indoor_temp_heating" {
|
||||
type = number
|
||||
description = "Minimum indoor relative humidity [%] required to run the fan"
|
||||
default = 50
|
||||
description = "Maximum cellar temperature [°C] below which heating with outdoor air is permitted. Above this, T_out must be <= T_in."
|
||||
default = 20.0
|
||||
}
|
||||
|
||||
variable "winter_temp_threshold_in" {
|
||||
type = number
|
||||
description = "Indoor temperature threshold [°C] below which winter mode is active"
|
||||
default = 14.0
|
||||
}
|
||||
|
||||
variable "winter_temp_threshold_out" {
|
||||
type = number
|
||||
description = "Outdoor temperature threshold [°C] below which winter mode is active"
|
||||
default = 10.0
|
||||
}
|
||||
|
||||
variable "target_humi_summer" {
|
||||
type = number
|
||||
description = "Target indoor relative humidity [%] during warm / summer mode"
|
||||
default = 40.0
|
||||
}
|
||||
|
||||
variable "target_humi_winter" {
|
||||
type = number
|
||||
description = "Target indoor relative humidity [%] during cold / winter mode (avoids over-cooling)"
|
||||
default = 50.0
|
||||
}
|
||||
|
||||
variable "urgent_humi_threshold" {
|
||||
type = number
|
||||
description = "Relative humidity threshold [%] above which ventilation is urgently evaluated 24/7"
|
||||
default = 60.0
|
||||
}
|
||||
|
||||
variable "night_window_start_hour" {
|
||||
type = number
|
||||
description = "Start hour (0-23) for the optimal dew point drying window"
|
||||
default = 3
|
||||
}
|
||||
|
||||
variable "night_window_end_hour" {
|
||||
type = number
|
||||
description = "End hour (0-23) for the optimal dew point drying window"
|
||||
default = 7
|
||||
}
|
||||
|
||||
variable "max_runtime_minutes" {
|
||||
type = number
|
||||
description = "Maximum continuous fan runtime in minutes before enforcing a cooldown pause"
|
||||
default = 90
|
||||
}
|
||||
|
||||
variable "min_pause_minutes" {
|
||||
type = number
|
||||
description = "Minimum rest period in minutes after a ventilation burst to allow thermal/humidity equilibration"
|
||||
default = 20
|
||||
}
|
||||
|
||||
variable "schaltzeit" {
|
||||
@@ -70,6 +124,7 @@ variable "critical_humi_ref_temp" {
|
||||
|
||||
variable "critical_humi_buffer" {
|
||||
type = number
|
||||
description = "Safety buffer [%] subtracted from the critical relative humidity threshold"
|
||||
description = "Safety buffer [%] subtracted from the critical relative humidity threshold for mold alert"
|
||||
default = 10
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue
Block a user