feat(monitoring): add prometheus metrics, alerts, and dashboard for taupi fan
This commit is contained in:
@@ -0,0 +1,83 @@
|
||||
apiVersion: v1
|
||||
kind: Service
|
||||
metadata:
|
||||
name: taupi-fan
|
||||
namespace: monitoring
|
||||
labels:
|
||||
app: taupi-fan
|
||||
spec:
|
||||
ports:
|
||||
- name: http-metrics
|
||||
port: 80
|
||||
targetPort: 80
|
||||
---
|
||||
apiVersion: v1
|
||||
kind: Endpoints
|
||||
metadata:
|
||||
name: taupi-fan
|
||||
namespace: monitoring
|
||||
labels:
|
||||
app: taupi-fan
|
||||
subsets:
|
||||
- addresses:
|
||||
- ip: 192.168.10.168
|
||||
ports:
|
||||
- name: http-metrics
|
||||
port: 80
|
||||
---
|
||||
apiVersion: monitoring.coreos.com/v1
|
||||
kind: ServiceMonitor
|
||||
metadata:
|
||||
name: taupi-fan
|
||||
namespace: monitoring
|
||||
labels:
|
||||
app: taupi-fan
|
||||
release: prometheus-operator
|
||||
spec:
|
||||
selector:
|
||||
matchLabels:
|
||||
app: taupi-fan
|
||||
namespaceSelector:
|
||||
matchNames:
|
||||
- monitoring
|
||||
endpoints:
|
||||
- port: http-metrics
|
||||
path: /script/1/prometheus
|
||||
interval: 30s
|
||||
scrapeTimeout: 10s
|
||||
---
|
||||
apiVersion: monitoring.coreos.com/v1
|
||||
kind: PrometheusRule
|
||||
metadata:
|
||||
name: taupi-fan-alerts
|
||||
namespace: monitoring
|
||||
labels:
|
||||
release: prometheus-operator
|
||||
spec:
|
||||
groups:
|
||||
- name: taupi-fan.rules
|
||||
rules:
|
||||
- alert: TaupiFanOffline
|
||||
expr: up{job="taupi-fan"} == 0
|
||||
for: 5m
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: "Id: {{ $labels.instance }} - TAUPI Fan Plug is unreachable"
|
||||
description: "The Shelly plug at 192.168.10.168 is unreachable by Prometheus. Check Wi-Fi connection or power status."
|
||||
- alert: TaupiFanSensorsStale
|
||||
expr: taupi_lost_connection_seconds_innen > 600 or taupi_lost_connection_seconds_aussen > 600
|
||||
for: 5m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: "TAUPI Fan BLE sensors stale"
|
||||
description: "The BLE sensors for temperature and humidity inside or outside have not sent new data for over 10 minutes."
|
||||
- alert: TaupiFanMoldDanger
|
||||
expr: taupi_is_critical == 1
|
||||
for: 30m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: "Cellar mold risk detected"
|
||||
description: "The cellar relative humidity has exceeded the critical mold threshold (inside humidity is high enough that mold can grow on cold wall surfaces)."
|
||||