# Shelly Fan Control Agent Documentation This directory manages the configuration, code templating, and deployment for the Shelly Plug S (Gen 3) that controls the cellar ventilation fan to prevent mold. ## Domain Structure & Key Files * **[main.tf](file:///Users/moritz/src/infrapuzzle/terraform_shelly/main.tf)**: Coordinates rendering the JavaScript template and executing the Python upload script. * **[variables.tf](file:///Users/moritz/src/infrapuzzle/terraform_shelly/variables.tf)**: Defines MAC addresses for the Bluetooth sensors, safety parameters, and the mold calculation coefficients. * **[scripts/Taupi-4.0.js](file:///Users/moritz/src/infrapuzzle/terraform_shelly/scripts/Taupi-4.0.js)**: The source Shelly control script containing the logic for parsing Bluetooth BTHome events, calculating dew points, evaluating mold danger, and switching the relay. * **[scripts/Taupi-4.0.templated.js](file:///Users/moritz/src/infrapuzzle/terraform_shelly/scripts/Taupi-4.0.templated.js)**: The locally generated script rendering the variables passed from Terraform. Do not edit directly. * **[scripts/upload.py](file:///Users/moritz/src/infrapuzzle/terraform_shelly/scripts/upload.py)**: Helper script executing during `terraform apply` to upload the templated script to the Shelly device over local HTTP RPC commands. ## Architecture Decisions ### 1. Linear Isopleth Approximation (LIM I) To determine if indoor relative humidity is high enough to warrant ventilation, we use a linear approximation of the **Lowest Isopleth for Mould (LIM I)** curve developed by Klaus Sedlbauer for biodegradable substrates (like wood or wallpaper). Between $5^\circ\text{C}$ and $25^\circ\text{C}$, the critical relative humidity threshold is calculated dynamically based on room temperature ($T$): $$RH_{crit}(T) = 80\% - 0.5 \cdot (T - 10)$$ * At $10^\circ\text{C}$, the critical threshold is $80\%$. * At $20^\circ\text{C}$, the critical threshold is $75\%$. ### 2. Room-to-Wall Safety Buffer (15%) Since the sensor measures ambient room air, but mold grows on colder outer wall surfaces, we must compensate for the thermal gradient. * **Physical Effect**: A $5^\circ\text{C}$ drop in temperature between room air ($20^\circ\text{C}$) and the wall surface ($15^\circ\text{C}$) causes the local relative humidity at the wall to spike from $60\%$ to $82\%$, crossing the mold germination threshold. * **Action**: We apply a **$15\%$ safety buffer** to the threshold. This targets keeping the ambient room air relative humidity below **$60\%$** (when the room is at $20^\circ\text{C}$) to keep wall surfaces safely below $80\%$ relative humidity. The fan is only allowed to run if: $$\text{humidity\_innen} \ge RH_{crit}(T) - 15\%$$ --- ## Sources & References * **[BoeserBob/Taupi-4.0](https://github.com/BoeserBob/Taupi-4.0)**: The original upstream Shelly dew point ventilation controller repository. * **[Klaus Sedlbauer Biography (Wikipedia)](https://de.wikipedia.org/wiki/Klaus_Sedlbauer)**: The researcher who developed the Lowest Isopleth for Mould (LIM) curves at Fraunhofer IBP. * **[WUFI Biohygrothermal Model](https://wufi.de/en/wufi-software/wufi-bio/)**: Fraunhofer IBP documentation explaining dynamic mold growth and spore germination models.